Rule Name Source Product Knowledge Link Description Severity
VSM6 - FMA - SUN4V-8002-LC CAM Applicable to all models SUN4V-8002-LC
The hardware has automatically reconfigured the link to isolate the failing lane, and successful
retransmission of the data has occurred.
2
VSM6 - FMA - SUN4V-8002-SP CAM Applicable to all models SUN4V-8002-SP
This error does not affect system operation. The error which could not be reported may have more serious
impact which cannot be determined.
2
VSM6 - FMA - SMF-8000-HP CAM Applicable to all models SMF-8000-HP No automated response. 3
VSM6 - JBOD - 78.5.624 CAM Applicable to all models 78.5.624 A disk has been removed. 2
VSM6 - FMA - SUNOS-8000-E8 CAM Applicable to all models SUNOS-8000-E8 Error reports have been logged for examination. 3
VSM6 - FMA - SPT-8000-7J CAM Applicable to all models SPT-8000-7J Server will be powered down when there are insufficient operational power supplies. 3
VSM6 - FMA - SUNOS-8000-AK CAM Applicable to all models SUNOS-8000-AK Future reboots could fail until this problem is corrected. 2
VSM6 - JBOD - 78.5.615 CAM Applicable to all models 78.5.615 A disk has been zoned out of view. 2
VSM6 - FMA - SUNOS-8000-DM CAM Applicable to all models SUNOS-8000-DM The service has been placed into the maintenance state. 2
VSM6 - FMA - SPT-8000-24 CAM Applicable to all models SPT-8000-24 System may be powered down if redundant fan modules are not operational. 2
VSM6 - FMA - SUN4V-8002-FY CAM Applicable to all models SUN4V-8002-FY No automated response. 2
VSM6 - FMA - PCI-8000-8S CAM Applicable to all models PCI-8000-8S One or more device instances may be disabled. 2
VSM6 - FMA - DISK-8000-6R CAM Applicable to all models DISK-8000-6R The IO service to this device may have been lost or degraded. 2
VSM6 - FMA - PCIEX-8000-T4 CAM Applicable to all models PCIEX-8000-T4 One or more device instances may be disabled. 2
VSM6 - FMA - SUN4V-8002-KQ CAM Applicable to all models SUN4V-8002-KQ No automated response. 2
VSM6 - FMA - PCIEX-8000-7H CAM Applicable to all models PCIEX-8000-7H One or more device instances may be disabled. 2
VSM6 - FMA - SUNOS-8000-KL CAM Applicable to all models SUNOS-8000-KL
The operating system has panicked and the system has rebooted. A crash dump and image of the operating
system at the time of failure has been produced for analysis. There may be a performance impact while
the panic is copied to the savecore directory. If the integrity of the operating system is compromised then
it is in no state to continue to provide service as doing so may lead to data corruption..
2
VSM6 - SW -
vsm.LogEvent.ILOM.2208
CAM Applicable to all models vsm.LogEvent.ILOM.2208 A server power supply input power state has changed from failed to OK. 2
VSM6 - FMA - SPT-8001-0D CAM Applicable to all models SPT-8001-0D Emergency backup power for FMODs is not available and system performance may be affected. 2
VSM6 - JBOD - 78.5.621 CAM Applicable to all models 78.5.621 A disk has gone into an unknown state. 2
Oracle Auto Service Request CAM Fault Coverage 9
Vista de pagina 8